Started By
Message

re: Connecting buildings with fiber

Posted on 1/24/24 at 2:40 pm to
Posted by dlmast87
Amish Country
Member since Dec 2007
1941 posts
Posted on 1/24/24 at 2:40 pm to
I was more so asking about pulling 800 ft of cable through the conduit....I've used a trencher before so I'm not too concerned about that.

Can it be done by hand or do you need to get some sort of mechanical puller?
Posted by lsu02150
BR
Member since May 2009
195 posts
Posted on 1/24/24 at 2:42 pm to
quote:

Also, is pulling 800 ft of cable going to be more difficult than I think? I don't want to underestimate this.


If laying new conduit, put a few mid run pull boxes every 100-200' or so and anywhere you have to make a turn. This will make pulling the fiber way easier and also make it much more serviceable if you need to replace the fiber for any reason in the future. You can find videos on YouTube of how to use either a shop vac or compressed air to get a pull string through each run. After a few hundred feet or through bends or turns, or with multiple cables, difficulty starts increasing fast.
Posted by Korkstand
Member since Nov 2003
28712 posts
Posted on 1/24/24 at 2:52 pm to
Add a bucket of cable lube to your amazon cart
Posted by notsince98
KC, MO
Member since Oct 2012
18073 posts
Posted on 1/24/24 at 2:57 pm to
quote:

Add a bucket of cable lube to your amazon cart


absolutely do this for anytime you pull cable through conduit. Cable is not designed to be pulled without it.
first pageprev pagePage 2 of 2Next pagelast page